    1.Our pumps could be 100% interchangeble with leading enterprise's Mark III series.2.The wet ends material like Titanium, Nickel, Hastelloy C, A20, CD4M, 316SS, Cast Steel etc are all available.BASEPLATE INSPECTION1. Remove all equipment.2. Completely clean the underside of baseplate. It is some


Overview of the light removal tower

1.Our pumps could be 100% interchangeble with leading enterprise's Mark III series.


2.The wet ends material like Titanium, Nickel, Hastelloy C, A20, CD4M, 316SS, Cast Steel etc are all available.



BASEPLATE INSPECTION

1. Remove all equipment.

2. Completely clean the underside of baseplate. It is sometimes necessary to coat the underside of the baseplate with an epoxy primer. This may have been purchased as an option.

3. Remove the rust preventative solution from the machined pads with an appropriate solution.

SITE / FOUNDATION

A pump should be located near the supply of liquid and have adequate space for operation, maintenance,and inspection.

Baseplate mounted pumps are normally grouted on a concrete foundation, which has been poured on a solid footing.

The foundation must be able to absorb any vibration and to form a permanent, rigid support for the pumping unit. The location and size of the foundation bolt holes are shown on the outline assembly drawing, provided with the pump data package.