ANSI B73.1 aftermarket specialists

Supported ANSI replacement parts, verified to fit.

Supported casing, cover, impeller, shaft and selected metallic mechanical-seal components for Goulds 3196, Durco Mark III and other ANSI B73.1 pumps—final scope follows engineering review of the model, drawing, material and interfaces.

  • 100% dimensional interchangeability
  • EN 10204 3.1 MTR and dimensional reports
  • Standard and exotic alloys cast in-house

No commitment · Partial pump data is welcome · Engineer-assisted identification

ANSI pump impeller dimensional inspection with digital caliper and engineering drawing
±0.02 mm critical dimension control
Engineering reviewScope and timing confirmed after identification
01
ANSI B73.1Supported dimensions
02
ISO 9001Controlled production
03
MTR 3.1Heat traceability
04
50+ CountriesExport support

Compatibility coverage

One supplier for your installed ANSI pump base.

Select a pump family to preview available coverage. Final interchangeability is confirmed against your model and position number.

SELECTED FAMILY

Goulds 3196 / 3196LF

Wet-end and supported component review across STX, MTX, LTX and XLT-X configurations.

Coverage
Supported casing, cover, impeller and shaft references
Fit
Fit verified by model, drawing and interfaces
Lead time
Confirmed with quotation
Verify My Part Number
CNC machining of a stainless steel pump impeller PMI alloy verification performed on a pump impeller
Traceablefrom heat number to shipment

Evidence before promises

Fit, metallurgy and documentation are verified—not assumed.

Each order follows an inspection route matched to the component and service risk. Documentation is delivered with the shipment.

01

Drawing and model review

OEM reference, frame, position number and critical interfaces are confirmed.

02

Material verification

Heat traceability plus PMI for exotic and corrosion-resistant alloys.

03

Dimensional inspection

CMM or calibrated inspection for critical fits and mounting dimensions.

04

Complete document pack

EN 10204 3.1 MTR, dimensional report and Certificate of Conformance.

Material capability

Match metallurgy to the process—not just the price.

Provide the fluid, concentration and temperature. The final material recommendation is reviewed by engineering.

ASTM A743

CF8M / 316SS

General chemical and food-grade service

ASTM A890

CD4MCuN

Chlorides and mixed acid applications

ASTM A743

CN7M / Alloy 20

Sulfuric acid and pickling operations

ASTM A494

CW6M / C-276

Severe chloride and reducing acid service

ASTM A494

M35-1 / Monel

Hydrofluoric acid and seawater

ASTM B367

Titanium Gr.2

Wet chlorine and oxidizing chlorides

ASTM A494

Nickel 200

High-concentration caustic service

ASTM B752

Zirconium 702C

Severe hydrochloric acid environments

Not sure which alloy is right?Ask an engineer

Supply options

Choose the right balance of traceability, cost and speed.

OEM Supply

Original manufacturer parts

For warranty-controlled equipment and procurement policies that require OEM sourcing.

  • OEM warranty
  • Original traceability
  • Longest standard lead time

Functional Replacement

Interchangeable fit and function

Cost-focused configuration for non-critical duties or urgent replacement needs.

  • Reviewed after identification
  • Engineer-reviewed substitutions
  • Competitive project pricing

Planning certainty

Production timing confirmed with the quotation.

Stock status and production route are confirmed with every quotation. Rush manufacturing is reviewed case by case.

Confirmed with quotationproduction route and timing follow part identification, material and inspection review
Part typeAvailabilityStandardExpedited
Supported standalone componentsConfirmed with quotationAfter identification and reviewConfirmed with quotation

From RFQ to shipment

A transparent aftermarket workflow

  1. 01

    Submit available data

    Part list, pump model, photos or drawings.

  2. 02

    Engineering verification

    Fit, metallurgy and service requirements.

  3. 03

    Quote and production

    Option comparison, lead time and inspection plan.

  4. 04

    Inspection and export

    Documents, protective packing and global shipment.

Request for quotation

Send what you have. We’ll help identify the rest.

Receive an engineer-reviewed response with pricing, confirmed lead time and recommended supply option after part identification.

  • Complete-pump, wet-end and supported component options
  • Material and interchangeability review
  • No commitment required
Attach drawings or parts lists by email:[email protected]
Engineering RFQComplete the form for engineering review and quotation
Aftermarket Engineering RFQ

Start with what you have. Only your name, work email, and the parts or support you need are required. Pump model, OEM numbers, material, quantity, and delivery date can be added if available.

By submitting this form, you acknowledge that the information provided will be used to respond to your inquiry and provide related technical or commercial support. See our Privacy Policy.

Your technical data is used only to prepare this quotation.

Procurement questions

What buyers usually ask before the first order

Final commercial and technical terms are confirmed in the quotation.

Are the parts guaranteed to fit?

Interchangeability is verified against the submitted pump model, position number and available dimensional data before the order is accepted.

What if I only have a nameplate photo?

Email the photo together with any available dimensions or service details. Engineering will confirm what can be identified and what additional information is needed.

Which certificates are supplied?

Depending on the component, the shipment can include EN 10204 3.1 MTR, PMI results, dimensional inspection and Certificate of Conformance.

Can you review obsolete ANSI pump components?

Yes, for supported component categories. We can review obsolete casing, cover, impeller, shaft and selected machined metallic seal components using an OEM reference, existing drawing, sample or controlled dimensions. Availability is confirmed after engineering review.

Quick Quote