Replacement ANSI Pump Impellers for Goulds 3196 & Durco Mark III
Replacement impellers for verified Goulds 3196 and Durco Mark III configurations. Identify the installed pump family, size, frame or Group, OEM reference, material and impeller diameter/trim. Our engineering team reviews fit and material before quotation. Normal installation and clearance checks still apply.
Start with the installed pump platform
Open-impeller route. Verify frame, size, OEM reference, diameter and material.
View 3196 Impeller Guide →POS 103 route for verified reverse-vane configurations. Verify Group, size, reference, trim and material.
View Mark III Impeller Guide →Search the exact OEM number and review the matched replacement reference.
Search OEM part number →Identify the component position, then follow the supported impeller route where applicable.
Open POS code finder →Identification routes by pump family
Swipe or scroll to see all columns.
Goulds 3196 impellers — 24 sizes, STX to XLTX
| Frame | Pump sizes covered | Impeller | Identification |
|---|---|---|---|
| STX | 1x1.5-6, 1.5x3-6, 2x3-6, 1x1.5-8, 1.5x3-8 | Open impeller, Item 101 | Frame + size + OEM reference + trim / material |
| MTX / LTX | 2x3-8, 3x4-8, 3x4-8G, 1x2-10, 1.5x3-10, 2x3-10, 3x4-10, 3x4-10H, 4x6-10, 4x6-10H, 1.5x3-13, 2x3-13, 3x4-13, 4x6-13 | Open impeller, Item 101 | Frame + size + OEM reference + trim / material |
| XLTX | 6x8-13, 8x10-13, 6x8-15, 8x10-15, 8x10-15G | Open impeller, Item 101 | Frame + size + OEM reference + trim / material |
Durco Mark III impellers — 30 sizes, Groups I to III
| Group | Pump sizes covered | Impeller | Identification |
|---|---|---|---|
| Group I | 1.5x1LF-4, 1.5x1-6, 3x1.5-6, 3x2-6, 1.5x1LF-8, 1.5x1-8, 3x1.5-8 | Reverse-vane impeller, POS 103 | Group + size + OEM reference + trim / material |
| Group II | 3x2-8, 4x3-8, 2x1LF-10, 2x1-10A, 3x1.5-10A, 3x2-10A, 4x3-10, 4x3-10H, 6x4-10, 6x4-10H, 3x1.5LF-13, 3x1.5-13, 3x2-13, 4x3-13, 4x3-13HH, 6x4-13A | Reverse-vane impeller, POS 103 | Group + size + OEM reference + trim / material |
| Group III | 8x6-14A, 10x8-14, 6x4-16, 8x6-16A, 10x8-16, 10x8-16H, 10x8-17 | Reverse-vane impeller, POS 103 | Group + size + OEM reference + trim / material |
33 replacement references — including Lo-Flo sizes — are listed with OEM part numbers on the dedicated guide.
Durco Mark III impeller guide — 33 references by size and OEM number
Fitment applies to a verified corresponding configuration. A pump family or POS code alone does not establish interchangeability.
Review photographs for the identified impeller
Product photographs can support an engineering review after the pump family, size, OEM reference, trim and material are identified. Photographs alone do not establish fitment or shipment history.

Open ANSI impeller
Replacement configurations with an open impeller.

Large ANSI impellers
Examples of large replacements and batch production.

Titanium reverse-vane impeller
Replacement configurations in specialty alloys.

Alloy 20 impeller
Manufactured to a drawing, sample or confirmed reference.

Large titanium impeller
Examples of large titanium impellers.

Custom replacement impeller
Replacement option based on an OEM reference, sample or drawing.
Material selection follows the service conditions
Material selection
Material is confirmed against fluid chemistry, concentration, temperature, solids and project specification. Commonly reviewed families include 316 stainless steel, CD4MCu, Alloy 20 and other verified alloys.
Manufacturing and dimensional inspection
Machining and dimensional inspection use the confirmed drawing, reference and mating interfaces. Dimensional records can support engineering release where applicable.
Dynamic balance and trim
Required diameter/trim, balance and configuration details are reviewed against the confirmed application and applicable pump documentation.
Lead time typically 30–50% shorter than OEM and total procurement cost 20–40% lower on like-for-like impeller scope; the schedule and price for your size and material are confirmed in the quotation. Every impeller is dynamically balanced before dispatch, with inspection records kept for traceability.
Don’t Know the Impeller Part Number?
A complete part number is not required to start. Send any available pump model/size, nameplate photo, old impeller photo or drawing, material, and current impeller diameter/trim. Reverse engineering from a sample or drawing is available when no OEM reference exists; sample-based work remains subject to engineering review.
What to send
- Pump model, frame/Group and size
- Nameplate or sectional drawing
- OEM/replacement reference if known
- Current material and impeller diameter/trim
- Fluid, operating details and quantity
- Removed-impeller and mating-part photos, if available
Frequently Asked Questions
Does ANSI B73.1 confirm that an impeller will fit?
No. ASME describes B73.1 interchangeability in terms of pump mounting dimensions, suction and discharge nozzle locations, input shafts, baseplates and foundation bolt holes. A B73.1 designation alone does not identify the correct replacement impeller. Verify the pump family, size, frame or Group, OEM reference, trim and material. Read the ASME B73.1 scope
What information helps identify a replacement?
Send the pump model and size, frame or Group, OEM part number if available, impeller diameter or trim, and material. A nameplate photo or drawing helps confirm the installed configuration.
Can you review an impeller without an OEM part number?
Yes. Send a clear photo, drawing or sample details with the pump model and size. Engineering will review what can be verified before quotation.
Why are the 3196 and Mark III routes separate?
The G196 / 3196 route covers open impellers identified by frame and size. The Mark III route covers reverse-vane impellers identified by Group and size. Use the matching guide to check the applicable reference and fitment details.
Which pump sizes do your replacement impellers cover?
For Goulds 3196, 24 sizes from 1x1.5-6 to 8x10-15G in STX, MTX, LTX and XLTX frames. For Durco Mark III, 30 sizes from 1.5x1LF-4 to 10x8-17 in Groups I, II and III, with 33 replacement references including Lo-Flo sizes. See the coverage tables on this page and send your pump size so we can confirm the exact impeller.
Can I order a single impeller on its own?
Yes. Impellers are supplied on their own, without a complete pump. Send the pump family, frame or Group, size, OEM reference if available, material and current trim diameter. Small fittings such as gaskets and O-rings are supplied fitted to their assemblies rather than on their own.
How long does a replacement impeller take?
Lead time is typically 30–50% shorter than OEM on like-for-like impeller scope. The schedule for your size and material is confirmed in the quotation after the reference review.
Identify the right impeller for your pump
Send the pump family, size and any reference you have — engineering reviews fit and material before we quote.
Prefer email? Send the pump family, size, OEM reference, material and trim to miya_zhang@ansipumpspro.com and we will identify the impeller for your quote.