Global ANSI Pump Replacement Solutions Supplier

G3796 Self-Priming Process PumpInterchangeable Replacement for Goulds 3796

A non-OEM replacement solution for installed Goulds 3796 self-priming process pumps. Match the corresponding STi / MTi size, verify dimensional interfaces, hydraulic duty, materials and seal configuration, then request a replacement quotation.

✓ 8 matching pump sizes ✓ STi / MTi frame route ✓ Dimensional fit review ✓ Complete pump + parts

Send the Existing Model, Size or Nameplate

If your inquiry already includes a Goulds 3796 model, pump size, material, seal requirement or delivery target, send it directly. We will review the replacement configuration and prepare the commercial quotation scope.

Goulds® and related model designations are used only to identify installed equipment and replacement requirements. ANSI Pumps Pro is an independent replacement pump and parts supplier and is not affiliated with or endorsed by the original equipment manufacturer.

G3796 self-priming replacement pump preview
G3796 · Self-Priming · Replacement Configuration
01 Existing Pump
Goulds 3796Start from model, size or nameplate.
02 Match
Size + FrameMap the corresponding STi / MTi configuration.
03 Verify
Fit + Duty + MaterialConfirm interfaces and operating requirement.
04 Supply
G3796 Pump / PartsQuote the reviewed replacement scope.

Find Your Existing Goulds 3796 Size

Choose the size on your existing pump. The page immediately maps it to the corresponding G3796 replacement route and shows the verified dimensional reference currently published on the page.

I only have a nameplate →
G3796 1 × 1.5-6
Replacement route identified
Existing modelGoulds 3796 1 × 1.5-6
FrameSTi
Discharge1 in
Suction1.5 in
A15.5 / 394
B5 / 127
D7.5 / 191
E4 / 102
X7.25 / 184
Preliminary replacement screening only. Final dimensional fit is confirmed against the approved drawing and the existing installation before order.

Match Your Existing Goulds 3796 Size

Existing documentation may use different frame-generation references. Start with the model designation and pump size shown on the nameplate, drawing or purchase specification. ANSI Pumps Pro reviews the submitted reference against the applicable G3796 replacement configuration before quotation.

Existing 3796 referenceSizeReplacement review routeQuote
Goulds 3796 ST-series reference1 × 1.5-6G3796 1 × 1.5-6Request This Size Quote
Goulds 3796 ST-series reference1.5 × 1.5-8G3796 1.5 × 1.5-8Request This Size Quote
Goulds 3796 MT-series reference2 × 2-10G3796 2 × 2-10Request This Size Quote
Goulds 3796 MT-series reference3 × 3-10G3796 3 × 3-10Request This Size Quote
Goulds 3796 MT-series reference4 × 4-10G3796 4 × 4-10Request This Size Quote
Goulds 3796 MT-series reference3 × 3-13G3796 3 × 3-13Request This Size Quote
Goulds 3796 MT-series reference4 × 4-13G3796 4 × 4-13Request This Size Quote
Goulds 3796 MT-series reference6 × 6-13G3796 6 × 6-13Request This Size Quote

Have a 3796 MTX or MTi Reference?

Older purchase specifications, drawings and installed-equipment records may contain frame-generation references such as MTX, while later documentation may use MTi/i-FRAME terminology. Submit the exact designation shown on your equipment or RFQ. We will verify the required frame, size and installation interfaces before confirming the replacement.

3796 dimensional replacement review illustration

Will the G3796 Fit My Existing Installation?

The replacement is not judged from the model name alone. We match the corresponding size and frame, then verify the interfaces that determine whether the pump can replace the installed unit with controlled modification risk.

Pump size
Existing 3796 designation
STi / MTi frame
Correct frame configuration
Suction interface
Size and location
Discharge interface
Size and location
Mounting interface
Feet, base and centerline
Drive interface
Shaft, coupling and motor arrangement
Interchangeable does not mean “order from model name only.” Final dimensional fit, hydraulic duty, material and seal arrangement are confirmed before order.
Hydraulic confirmation

Confirm the Required Duty Before Final Selection

The replacement is confirmed against the selected pump size and the actual operating requirement. Send the required flow, head, speed or frequency, and suction conditions where available. The applicable curve and quotation scope will be reviewed for the selected configuration.

Selected size1 × 1.5-6 · STi
Curve reviewMatched to selected configuration
Self-priming dutySuction conditions reviewed
Engineering outputCurve + model + quotation scope
Request Performance Curve Review

Define the Required Wet-End Material and Seal Arrangement

Select the material requested by your specification or describe the process conditions if material selection still requires review. Final component materials and seal arrangement are confirmed for the selected pump size before quotation release.

Requested Wet-End Material

Choose the specified material. Availability is confirmed for the selected size and configuration.

Final component availability and seal arrangement are confirmed for the selected G3796 size, specified material and process conditions.
Check Selected Material →

Construction Items We Confirm

Component / itemRFQ handling
Casing / Wet EndConfirmed by selected size and requested material
ImpellerConfirmed by selected size and requested material
Seal Chamber / CoverConfirmed for required seal arrangement
Shaft / SleeveConfirmed for requested construction
Mechanical SealReviewed against fluid, temperature and arrangement
Fasteners / TrimDefined in final quotation BOM where applicable

How the 3796 Self-Priming Arrangement Supports the Application

The self-priming casing retains the liquid required for the priming cycle and separates air from the pumped liquid during startup. Final suitability still depends on the selected size, suction arrangement and operating conditions.

How the 3796 self-priming cycle works
Self-priming does not mean dry-running. The required priming charge and suction conditions must be confirmed for the actual system.

Complete G3796 Replacement Pump

Submit the existing pump reference and required configuration. The quotation will define the reviewed pump size, construction, seal arrangement, supply scope and required technical documentation.

✓ Complete pump assembly✓ Selected wet-end construction✓ Seal configuration✓ Performance curve / technical documentation✓ Motor / coupling arrangement review✓ Approved drawing confirmation where applicable
Request Complete Pump Quote

3796 Replacement Parts

If the project requires supported individual parts instead of a complete pump, send the existing pump model, size, OEM part number, drawing or sample details where available. Standalone scope is limited to casing, impeller, applicable cover, shaft and selected drawing-based metallic seal components.

3796 supported replacement-part review Send 3796 Part Number

From Existing 3796 to Replacement Quote

STEP 01
Identify Existing Pump

Send the model, size, frame/reference, nameplate, serial number or drawing available from the installed unit.

STEP 02
Confirm Interchangeability

Review dimensional interfaces, hydraulic duty, construction, seal arrangement and installation requirements.

STEP 03
Define Supply Scope

Confirm complete pump, bare pump, wet end or supported individual parts and required documentation.

STEP 04
Receive Proposal

Receive the reviewed model/configuration, commercial quotation and required next-step documentation.

What You Receive With the Pump Quotation

Procurement teams often need more than a model number. The quotation package should clearly identify the reviewed replacement configuration and the commercial information required to evaluate the purchase.

01

Pump Configuration

Reviewed model, size, construction and supply scope

02

Price

Unit pricing and quantity basis

03

Delivery

Quoted production lead time

04

Weight

Reference/net weight where applicable and final shipping weight when the quoted configuration is confirmed

05

Packing

Packing method and packing dimensions when available for the final shipment scope

06

Technical Documents

Performance curve, drawing and material/inspection documentation according to quotation scope

Weight note: Bare-pump reference weight is not the same as final gross shipping weight. Final shipping weight and packing dimensions are confirmed against the quoted configuration and packing scope.

Request a Goulds 3796 Replacement Quote

Start with the information already available in your RFQ, nameplate, drawing or pump specification. For an installed 3796, the fastest route is the existing-pump replacement form. Engineering will request additional operating data only when needed to confirm the final configuration.

Tell us what you are replacing

Choose the fastest path for your project. Existing 3796 replacement is the default.

3796 Replacement Questions

Can the G3796 replace an installed Goulds 3796?

The page is intended for corresponding Goulds 3796 replacement reviews. Final interchangeability is confirmed against the submitted pump size/reference, installation interfaces, hydraulic duty, material and seal arrangement before order.

Can I request a quote with only a nameplate or existing RFQ?

Yes. Send the nameplate, RFQ, drawing, datasheet or the model and size information you already have. Engineering can request additional details only where needed for final confirmation.

Can you review a 3796 MTX or MTi reference?

Yes. Submit the exact frame/reference shown on the installed pump or purchasing document. The required frame, size and interfaces are verified during replacement review rather than assumed from the designation alone.

Can I request Alloy 20 construction?

Alloy 20 / CN7M can be submitted as the specified material requirement. Final component construction is confirmed for the selected size and seal arrangement during quotation review.

Can you review a single cartridge mechanical seal requirement?

Yes. Include the existing seal reference or required seal arrangement where available. Final seal selection is reviewed against the pump configuration, process fluid, temperature and operating conditions.

Will the quotation include shipping weight?

Shipping information can be included in the commercial quotation. Bare-pump reference weight and final gross shipping weight are different values; final shipping weight and packing dimensions are confirmed for the quoted configuration and packing scope.

What if my specification says no substitute or equivalent?

Select “Genuine OEM Only / No Substitute” in the RFQ form. ANSI Pumps Pro specializes in independent replacement pumps and components, so the requirement should be reviewed before quotation to confirm whether it can be supported.

Quick Quote