Select a semiconductor chemical pump for the fluid and its point of use. The pump must withstand the fluid and keep its contribution of metals, particles, and other contaminants within the process limits. Review the entire wetted path, including the casing, impeller, seals, gaskets, and fittings.

Pump duties and contamination limits

A fab may handle the same chemical in a bulk storage area and at a tool that dispenses it onto a wafer. Flow, dosing accuracy, and contamination limits can differ between those points. Identify where the pump will operate before specifying materials or comparing pump types.

  • Bulk transfer and distribution. Define flow, total dynamic head, concentration, and temperature during normal operation, startup, and cleaning. Consider an alloy ANSI centrifugal pump for bulk or auxiliary service when the specific build meets the requirements for that part of the system.
  • Point-of-use supply and dosing. Specify flow stability, allowable pulsation, and limits for metals and particles. Compare wetted constructions such as PFA or PTFE and choose a pump type that can deliver the required flow and dosing accuracy.
  • Chemical mechanical planarization (CMP). The particles in a CMP slurry perform the polishing. Check how pumping and recirculation affect particle size distribution, agglomeration, settling, and particles shed by pump wear. Entegris CMP resources.
  • Ultrapure water (UPW). Set quality limits at the point of use and assess the pump’s contribution alongside the other components in the loop. Depending on the process, the specification can cover particles, metals, and total organic carbon. SEMI F63 guidance for ultrapure water.

What to verify for each fluid

Document the concentration and temperature of the liquid that will actually pass through the pump. Record the stock chemical, diluted solution, and process mixture separately. Check the complete wetted configuration against both the chemical compatibility requirements and the line’s contamination limits.

On small screens, scroll the table to see all columns.

Fluid Service data What to verify
Hydrofluoric acid (HF) Actual concentration, temperature, and chemical grade. Verify chemical compatibility and extractable metals for the full wetted configuration, including seals and connections. SEMI C28 for HF grades.
Sulfuric acid (H2SO4) Concentration and temperature ranges. Identify dilution or mixing with other reagents. Request corrosion data for the full operating range. Check the gaskets and seal along with the casing alloy.
Hydrogen peroxide (H2O2) Concentration, grade, and handling requirements from the chemical supplier. Verify materials and cleanliness to control contaminants that can accelerate decomposition. Evonik hydrogen peroxide handling guidance.
Ammonium hydroxide (NH4OH) Concentration, temperature, and composition when part of a mixture. Confirm compatibility with the actual solution and check the pump’s contribution of metals and particles against point-of-use limits.
Phosphoric acid (H3PO4) and nitric acid (HNO3) For each acid, specify grade, concentration, and temperature, including operating variations. Qualify each service with its own corrosion and cleanliness data. Identify the exact alloy grade and every wetted part.
CMP slurries Formulation, pH, solids content, particle size, and recirculation conditions. Check slurry stability in the loop and assess the particles that pump wear can introduce.
Ultrapure water (UPW) Temperature and point-of-use water quality requirements. Verify the materials and cleanliness of the complete loop. SEMI F57 for polymer components.

Wetted materials and surface finish

When comparing a metal alloy with a fluoropolymer construction, request the full list of wetted materials. For a lined pump, also check joints, seats, seals, and locations where liquid can collect. Qualify the assembly that will actually be installed.

If the service permits stainless steel, specify a surface finish where it matters for cleaning. Give the Ra value with units and identify the surfaces to measure. Document electropolishing and passivation separately from liquid contamination tests. ASTM B912 for passivation by electropolishing and ASTM A967/A967M for passivation treatments.

For dimensional interchangeability, specify ASME B73.1 where applicable to the horizontal end-suction centrifugal pump. Put purity limits in the project acceptance specification. Scope of ASME B73.1.

Tests and records for pump acceptance

  1. Material identification. Request the wetted parts list, material grades, and any certificates or traceability records required by the project. An alloy composition certificate and an extractables report serve different acceptance criteria.
  2. Extractable metals. Agree on the elements to measure, such as iron, nickel, chromium, or copper, and specify the test fluid, temperature, exposure time, method blank, and quantitation limits. Request results for the proposed configuration. SEMI C90 for extractable metals from fluoropolymers and distribution components.
  3. Particles and cleanliness. Specify particle size bands and count limits in the liquid. Where applicable, add a total organic carbon limit and request cleaning, drying, and packaging procedures with identification of the equipment tested.
  4. On-site acceptance. Define the sampling point and operating conditions. Agree on the point-of-use acceptance criteria and assign responsibility for verifying them after installation.

What to include in the pump specification

Start with the fluid data sheet and a diagram of the relevant section of the system. Include concentration, minimum and maximum temperatures, flow, total dynamic head, suction conditions, restricted materials, and contamination limits. For a replacement, add the existing model, mounting dimensions, and seal arrangement.

Use the chemical resistance guide for initial materials screening and the specialty alloy ANSI pump catalog to review transfer pump configurations.