DURCO MARK 3 · UNITIZED SELF-PRIMING REPLACEMENT

Durco Mark 3 Unitized Self-Priming Replacement Pump

ANSI Pumps Pro offers an aftermarket alternative for the Durco Mark 3 Unitized Self-Priming pump, built on a D Mark III power end. To determine whether the replacement is dimensionally interchangeable, send the installed pump’s nameplate and outline drawing with the suction conditions, duty and material requirements.

Start with what you have. Unknown details can be confirmed during review.

Durco Mark 3 Unitized Self-Priming replacement pump — unitized priming-chamber ANSI B73.1 pump

01 / CHECK THE INSTALLED PUMP

Can this replace your existing pump?

Use the installed pump data to check the proposed replacement pattern. Send the information you have; engineering can identify missing details.

Start a quote →

01

Installed modelConfirm the D Mark III power-end size, group and unitized configuration.
02

Suction arrangementShare static suction lift, suction-line layout and priming / restart requirements.
03

Operating pointProvide required flow, head, liquid and temperature.
04

Materials and fitIdentify material, seal, baseplate, nozzle and connection requirements.

Fit is confirmed against the exact size, configuration, duty and installation data. The model name alone is not an interchangeability guarantee.

02 / VERIFY REQUIREMENTS

Check model, parameters and materials

We compare the installed data with the proposed replacement configuration before confirming fit and quotation scope.

Materials are service-specific

Wet-end material selection depends on the pumped liquid and operating conditions.

Request a Quote ↘

PRODUCT DETAILPUBLISHED DATA / QUOTE CHECK

Select a row to see what information helps confirm fit and prepare a quote.

Standard / patternANSI/ASME B73.1 · non-OEM replacement for the Durco Mark 3 Unitized Self-Priming dimensional pattern
FIT CHECKSend the installed nameplate and outline drawing to review the exact configuration and interfaces.
Power endD Mark III power ends; exact size and group require nameplate / drawing confirmation
FIT CHECKProvide the installed size/group, frame and power-end reference for review.
ConstructionUnitized self-priming configuration with a priming chamber
FIT CHECKShare the chamber arrangement and suction piping details, including initial prime and restart conditions.
Wet-end materialsDuctile Iron / 316SS (CF8M) / CD4MCu / Alloy 20 (CN7M) / Other alloy on request
FIT CHECKProvide liquid composition, concentration, temperature, solids and existing material specification to confirm the exact option.
iCheck fit against the installed pump size and outline drawing. The reference and installation notes below explain what to compare.

Size and drawing review — Send the size and group shown on the installed nameplate, along with the outline drawing. The elevated suction nozzle makes its position part of the fit check. Start with your nameplate details.

The original: Flowserve Durco Mark 3 Unitized Self-Priming pump

Reference data for the installed OEM pump, from Flowserve Bulletin PSS-10-13.8 (E). These figures describe the original Durco Mark 3 Unitized Self-Priming pump — they are the pattern this replacement is checked against, not ratings of the ANSI Pumps Pro unit.

  • Flows to 320 m³/h (1,400 gpm); heads to 120 m (400 ft)
  • Pressures to 20 bar (285 psi, flange-rating dependent); temperatures to 370 °C (700 °F)
  • Static suction lift to 6 m (20 ft) at sea level, on water at ambient temperature
  • Unitized casing — priming chamber, air separator and volute in one casting; no external priming tank and no foot valve. The casing keeps its priming charge after shutdown, so the pump re-primes itself on restart.
  • Reverse vane impeller with external micrometer adjustment — running clearance is set against the rear cover and can be reset from outside the bearing housing, without disturbing piping or alignment.
  • SealSentry seal chambers and the standard Mark 3 power end — the bearing frame, shaft and bearings are the standard Mark 3 power end, shared with the flooded-suction Mark 3.
  • Applications on record: sump service, tank car unloading, duplex lift stations, waste acid and lagoon transfer — services where the liquid source sits below the pump and a flooded suction cannot be maintained.

Check the installed model’s pressure–temperature chart for its casing material and flange class. Catalog maxima do not apply simultaneously.

Sources: Flowserve Bulletin PSS-10-13.8 (E), July 2007; Flowserve Durco Mark 3 brochure PS-10-13 (E), Unitized Self-Priming section. Retrieved 2026-11-15. OEM figures are quoted for identification and fit-checking only.

03 / REQUEST PRICING

Have a nameplate? Start your quote.

Send your pump size, duty point, material requirement and quantity. If available, send a nameplate, curve or drawing by email. Leave unknown fields blank and we will follow up.

Request a Quote ↘

Priming and installation checks

The original Mark 3 Self-Primer runs on the standard Mark 3 power end. Whether the replacement power end, or a power-end-only supply, fits your installed wet end is confirmed against the installed group and drawing before quotation.

The wet end is self-primer specific — the unitized casing and its rotating parts are not standard Mark 3 parts. Exact part scope is confirmed against the installed size and part numbers before quotation.

D Mark III unitized self-priming pump, drive-end view — bearing frame and casing joint
Three-quarter view from the drive end — bearing frame, casing joint and shaft.
  1. Elevated suction connection. The discharge stays top-centreline, but the suction nozzle sits high on the unitized casing, not on the shaft centreline. Replacing a standard end-suction pump — or re-piping an existing installation — needs a suction spool check against the outline drawing.
  2. Larger casing envelope. The priming reservoir makes the casing taller and wider than a standard B73.1 casing of the same group. Baseplate bolt patterns and shaft centreline heights follow the frame group; casing clearances do not — check the envelope, not just the feet.
  3. Discharge air path. During priming, the pump pushes the suction-line air out through the discharge. A closed check valve or a pressurised discharge column blocks that path — if your discharge cannot vent, an air-release bypass back to the sump has to be part of the installation.

For the low flow configuration, see the Durco Mark 3 Lo-Flo replacement pump.

Mark 3 Unitized Self-Primer or Goulds 3796?

The two ANSI self-priming patterns a procurement engineer is most likely to be holding a quote against. Both are unitized-casing, B73.1-derived self-primers that share their power ends with their standard lines (Mark 3 and 3196). They are not piping drop-ins for each other.

Original equipment comparison
Parameter Durco Mark 3 Unitized Self-Primer Goulds 3796
Impeller Reverse vane, clearance set against the rear cover Open impeller, clearance set against the casing
Clearance adjustment External micrometer carrier Jackbolts on the bearing-housing carrier
Max capacity 1,400 gpm (320 m³/h) 1,250 gpm (284 m³/h)
Max head 400 ft (120 m) 430 ft (131 m)
Max static suction lift 20 ft (6 m) 20 ft (6 m)
Max pressure 285 psi (20 bar), flange-rating dependent 375 psig (2,586 kPa), per OEM bulletin
Power-end family Durco Mark 3 (Groups 1–2) Goulds 3196 (STX / MTX / LTX)

Sources: Flowserve Bulletin PSS-10-13.8 (E), July 2007; Goulds Pumps Form B3796, June 2008, and Model 3796 i-FRAME installation, operation and maintenance manual. The figures are OEM catalog limits. Check the configuration-specific rating and pressure–temperature limits for the installed unit.

Same nominal size does not mean same nozzles. Suction elevation, casing footprint and the coupling gap differ between the two castings, so converting an installed 3796 to a Mark 3-pattern unit (or the reverse) needs spool and baseplate checks against both outline drawings. If your installed pump is the Goulds unit, start from the 3796 page instead.

Replacement parts for installed Mark 3 Self-Priming pumps

Part-level supply for installed Mark 3 Self-Priming pumps is confirmed per part number — send the OEM part number, size and group and engineering will confirm scope before quotation.

Use the OEM part number cross-reference to identify the reference to include in your request.

D Mark III unitized self-priming pump, suction-side view — unitized casing and oil sight glass
Suction-side view: the one-piece casing holds the priming chamber above the volute.

Frequently asked questions

What information is needed for suction-lift review?

Provide static lift, suction-line size and layout, liquid and temperature, startup / restart requirements, and required flow and head. Nameplate and installation photos are useful.

Are pump dimensions and priming limits available?

The operating envelope above is for the original Flowserve pump. Send the installed size, nameplate and duty to review the configuration-specific outline drawing and priming data for the replacement.

Can the existing base and connections be reused?

That depends on the installed dimensions, nozzle orientation, baseplate and proposed configuration. Include drawings or clear photos so these interfaces can be checked.

Is a unitized self-priming pump just a standard Mark 3 with a priming tank added?

No. The priming chamber, air separator and volute are one casting — there is no bolt-on tank and no external priming device. Before the first start, fill the casing with priming liquid. On start-up the impeller recirculates the liquid held in the casing, entrains the air from the suction line and vents it through the discharge until the pump is fully primed. After shutdown the casing keeps its charge, so the next start re-primes automatically. The power end, however, is the standard Mark 3 power end — that part of the pump is the standard machine.

Can this pump replace a Goulds 3796?

Both OEM patterns are ANSI self-priming pumps with up to 20 ft of published static suction lift. Their maximum catalog flows differ, and their nozzle coordinates, suction elevation and casing footprint require a spool and baseplate check against both outline drawings. Send the installed nameplate and drawing. To stay with the Goulds pattern, see the Goulds 3796 replacement pump page.

What sizes are available, and how high can it lift?

Send your installed size and group so engineering can confirm supply against the nameplate before quotation. The original Durco pump has a published maximum static suction lift of 20 ft at sea level on water. The achievable lift for your installation depends on the suction line and liquid temperature. Include the suction layout with your inquiry.

← Back to pump products

04 / UNITIZED SELF-PRIMING QUOTE REQUEST

Request a Unitized Self-Priming replacement quote

Describe the installed unitized pump, suction-lift conditions and installation interfaces. We will review the required duty, material and configuration before confirming fit and quotation scope.

Helpful for fit review. Nameplate, static lift, suction-line layout, nozzle orientation and base / outline drawing.

Durco Mark 3 Unitized Self-Priming Replacement Pump Quote Request

By submitting this form, you acknowledge that the information provided will be used to respond to your inquiry and provide related technical or commercial support. See our Privacy Policy.

No duty data yet? Send what you have — engineering will ask for the rest by email.
Or email your inquiry directly: miya_zhang@ansipumpspro.com

By submitting this form, you acknowledge that the information provided will be used to respond to your inquiry and provide related technical or commercial support. See our Privacy Policy.

Quick Quote