Durco Mark 3 Unitized Self-Priming Troubleshooting: No Prime, Lost Prime & Slow Restart

Start with when the failure occurs. A pump that never establishes prime, one that loses flow as the tank level drops, and one that only struggles after a long shutdown give you different clues. This guide applies to the Flowserve Durco Mark 3 Unitized Self-Priming ANSI configuration. Use the installed nameplate and drawing to confirm the model before applying any clearance or ordering parts.

Horizontal Self-Priming Process Pump — ANSI B73.1 integrated self-priming
Engineering source review Replacement-data workflow Updated Nov 15, 2026

Find your symptom

Never establishes flow
Confirm the initial casing fill, the discharge air path and suction-side tightness.
Flow starts, then drops
Compare tank level, inlet submergence and gauge readings at normal flow and at the point of failure.
Slow after standing idle
Check whether the casing retains its liquid charge. Compare short and long shutdowns under similar conditions.
Failure starts after repair
Verify the fitted casing and impeller, actual trim, radial cutwater clearance and axial clearance.

Stop and follow the site procedure if the pump fails to establish flow within its approved startup limits. Before opening the pump or piping, isolate and lock out the equipment, relieve pressure and drain or decontaminate it as required for the process fluid.

How the unitized priming cycle works

The integral casing contains the priming chamber, air separation area and volute. During startup, liquid circulates back to the impeller while separated air leaves through the discharge side. A pump can have a full priming chamber and still fail if that air has nowhere to go.

Air enters from the suction line and mixes with liquid at the impeller. Air separates and exits on the discharge side, while liquid returns through the priming chamber.
Figure 1. Air and liquid paths during self-priming. Functional schematic based on the Flowserve ANSI brochure, pp. 28–29. View full-size diagram

For the initial prime, Flowserve specifies filling the casing to the bottom of the suction nozzle (IOM §5.6). Once process liquid reaches the pump and flow stabilizes, use the pump and system curves to check the operating point.

The pump starts but never establishes prime

  1. Confirm the initial liquid charge. Verify the fill against the applicable IOM. A drained casing, or one emptied after service or shutdown, may need to be refilled.
  2. Trace where the air goes. Check the discharge piping, any check valve and the existing bleed path against the piping drawing. A liquid-filled discharge line or closed check valve can trap air. Flowserve discusses a bleed line where air cannot vent freely. Route process vapors according to the plant’s approved design.
  3. Check the suction side for air ingress and restrictions. Inspect joints, gaskets and seal-chamber interfaces. A joint under vacuum can draw air without visibly leaking liquid. Record the condition of the intake and any installed strainer, along with the actual lift and suction pipe layout.
  4. Verify the pump configuration. If the fault started at commissioning or after repair, have maintenance verify rotation, speed and fitted wet-end parts against the installed documentation.

Flowserve’s IOM §§4.6.2.1 and 4.6.3.1 explain why pipe geometry matters. Longer or larger suction piping contains more air to evacuate. The suction piping and seal chamber also have to hold vacuum for the pump to prime.

The pump primes and then loses flow

Record the source level, suction pressure or vacuum, discharge pressure, speed and measured flow while delivery is stable and again when it drops. Include gauge locations and units. A falling liquid level increases static lift and can reduce inlet submergence. If the problem repeats near the same tank level, check for vortexing and entrained air at the intake.

If the source level stays steady, compare the readings with those from a normal run at the same speed and valve lineup. A suction restriction, air ingress, higher liquid temperature or a change in discharge conditions can produce overlapping symptoms. Include liquid temperature and available net positive suction head (NPSHA), when known, for comparison with the selected pump curve. A pump that establishes prime but delivers low head also needs a duty-point check, including speed, trim and system head.

Restart takes longer after a shutdown

Compare the time to steady delivery after a short stop and after a longer idle period. Record source level and valve lineup for both. If the casing has lost its charge after standing, trace possible drainback or siphoning through the installed piping, check valve and air release arrangement. If the charge remains, review the air path and the suction volume before attributing the delay to wear.

The Flowserve brochure lists up to 20 ft (about 6 m) of static suction lift for the original ANSI unitized series. That is a catalogue limit. Confirm the actual lift, priming time and operating duty for the proposed size, liquid, speed and piping.

Priming changes after impeller or casing work

Radial clearance runs from the impeller outside diameter to the casing cutwater. Axial clearance is measured to the rear cover for a reverse-vane impeller and to the casing for a front-vane open impeller.
Figure 2. Radial and axial clearance reference points. Measurement locations only. Schematic, not to scale. See Flowserve IOM Fig. 5-12 and §6.6. View full-size diagram

Radial clearance at the cutwater

Measure the gap between the impeller outside diameter and the casing cutwater, the point where the volute meets the discharge. Flowserve’s 08-06 IOM §6.6 specifies 3 mm (0.125 in., as listed) for the original unitized pump. Check the installed drawing and revision before applying the dimension.

Axial impeller clearance

The reference surface depends on impeller design. In this manual, reverse-vane clearance is set from the rear cover, while the front-vane open impeller on the unitized pump is referenced to the casing. Use the applicable temperature setting and procedure in Fig. 5-12 and §6.6.

Record the actual impeller diameter and both clearances before adjusting anything. An impeller trim or casing change can affect the radial gap even if the axial setting was made correctly. The IOM’s Group 2 unitized drawing in §8.5 is a reference for identifying parts. Order using the full size, group, serial number and the drawing applicable to the installed unit.

What to send for a replacement review

  • Pump identity: full nameplate, Group, size, serial number, actual impeller diameter and installed outline drawing.
  • Suction system: normal and minimum source levels, static lift, suction pipe size and layout, and the air release route.
  • Operating data: suction and discharge readings, flow, head, speed, liquid, temperature, solids, materials and seal details.
  • Fault history: time to steady delivery, idle time before a failed restart, recent repair details and the requested scope: complete pump, wet end or parts.

For an installed pump that needs replacement, use the Durco Mark 3 Unitized Self-Priming replacement pump page to review the suction layout, fit and supply scope.