Complete replacement pump
G196 CV assembly for the installed CV3196 size and frame.
The G196 CV combines a recessed impeller and non-clog casing with the G196 power end. Send your pump size or nameplate to start a CV3196 replacement enquiry.
Dimensional interchangeability applies to the same pump size and frame.
The G196 CV is a non-clog ANSI/ASME B73.1 chemical process pump built to the Goulds CV3196 pattern. A vortex impeller sits back from the main flow passage, allowing the pump to handle liquids containing solids or fibres.
Jinan Yingsiman Machinery Co., Ltd. manufactures the G196 CV as a non-OEM replacement pump and supplies replacement parts for installed CV3196-type pumps.
Recessed-impeller pumps are used for fibrous slurries, fragile crystals and liquids with entrained air or gas. Select the pump from the duty point and applicable performance curve.
The CV3196 is built on the 3196 platform: in the OEM design it uses every Goulds 3196 part except the casing and the impeller, and a retrofit kit of CV casing and recessed impeller converts an existing 3196 into the non-clog configuration. If your installed 3196 clogs or wears on fibrous or solids service, send its size, frame and nameplate details — the conversion scope for your pump can be reviewed against the CV size and frame table below before quotation.
Send a nameplate photo or the pump size and frame, plus any part numbers or drawings. We check the dimensions, duty point, material and seal arrangement before quotation.
A matching G196 CV retains the baseplate position, suction and discharge flange positions, coupling height and motor position. The casing and recessed impeller follow the installed CV pattern.
Bearing frame, bearing housing, shaft, sleeve and seal-chamber references use the G196 general-purpose pump’s position numbers.
See G196 power-end references ↗CV wet-end part references depend on pump size. Include the installed part numbers with your enquiry.
The CV3196 family has seven hydraulic sizes across four i-FRAME power ends (legacy X-Series frame names are shown in the notes). Dimensions A, B, D and X and the bare-pump weight are OEM reference values from the Goulds CV 3196 i-FRAME brochure for the corresponding size — use them to check your installation space and lifting arrangement, not for construction. Final fit is confirmed against the nameplate and the approved drawing before quotation.
7 sizes in the reference list
| Group | Size | A | B | D | X | Bare Pump Weight | Quote |
|---|---|---|---|---|---|---|---|
| STi | 2x2-8 | 15.38 (391) | 2.75 (70) | 5.25 (133) | 6.50 (165) | 140 (65) | Request This Size Quote |
| MTi / LTi | 2x2-10 | 21.75 (552) | 3.50 (89) | 8.25 (210) | 8.50 (216) | 260 (120) | Request This Size Quote |
| MTi / LTi | 3x3-10 | 22.50 (572) | 4.25 (108) | 8.25 (210) | 9.00 (229) | 280 (125) | Request This Size Quote |
| MTi / LTi | 2x3-13 | 22.38 (568) | 4.12 (105) | 10.00 (254) | 10.50 (267) | 360 (165) | Request This Size Quote |
| MTi / LTi | 3x4-13 | 22.81 (579) | 4.12 (105) | 10.00 (254) | 10.50 (267) | 410 (185) | Request This Size Quote |
| LTi | 4x6-13 | 23.13 (588) | 4.75 (121) | 10.00 (254) | 11.50 (292) | 430 (194) | Request This Size Quote |
| XLTi | 6x8-15 | 32.5 (826) | 6.5 (165) | 14.5 (368) | 14.00 (356) | 486 (219) | Request This Size Quote |
No matching sizes.
Dimensions: inches (mm). Bare pump weight: lbs (kg).
Frame notes: the four mid sizes (2x2-10, 3x3-10, 2x3-13, 3x4-13) appear under both MTi and LTi power ends in the OEM dimensions table; shaft diameters differ by power end (see Construction Details), so the bearing-frame nameplate — not the hydraulic size alone — decides the frame. Legacy frame names: STX = STi, MTX = MTi, LTX = LTi, XLT-X = XLT-i.
Order a complete pump, a CV wet-end assembly or the individual parts listed below.
Standalone parts scope: the recessed impeller, the casing and cover, the shaft and shaft sleeve, and cartridge mechanical seals can be supplied on their own. Small parts — seal rings, gaskets, bearings, oil seals and similar — are not shipped on their own; they are supplied fitted to their assemblies.
Select a supply scope here, then use Request a Quote below.
G196 CV assembly for the installed CV3196 size and frame.
The recessed-impeller wet end for the installed pump size.
Non-clog casing for the CV recessed-impeller layout.
Send the cover drawing or part reference.
CV impeller for induced-vortex operation.
Shafts and shaft sleeves matched to the installed frame, and cartridge mechanical seals reviewed against the fluid, temperature and seal arrangement.
An induced vortex carries most of the liquid through the casing, limiting direct contact with the impeller vanes. Solids passage depends on pump size, particle shape and duty.
The casing provides an open passage from suction to discharge for solids-bearing liquids.
Less direct impeller contact helps limit damage to crystals, flocs and food-grade solids. Specify any process or hygiene requirements with the duty data.
Options include labyrinth bearing isolators and SKF or equivalent bearings for the selected arrangement.
Ask about hard-metal or high-alloy impellers when selecting for wear as well as corrosion.
The concentric (circular) casing cuts radial loads by as much as 85% compared with an expanding-volute casing at low flows (OEM brochure figure), so the pump runs reliably at throttled duty where conventional end-suction pumps load their bearings and seals.
Impeller clearance is adjusted externally, restoring the original flow, pressure and efficiency without opening the casing; the back pull-out design lets the rotating assembly be serviced without disturbing the piping. Flush and drain connections can be specified so the casing and impeller can be cleaned in place.
Reference maximums for initial selection.
Maximum flow, head, pressure and temperature do not describe a single operating point. Use the curve and material limits for the selected pump.
Gas and solids: the OEM selection guide rates this design for liquids containing 10–20% entrained air or gas. For solids, the OEM wording is that anything that can exit the discharge will pass through the pump — there is no single family maximum solids size, because passage depends on the selected size and duty.
| Item | Part Name | Ductile Iron / CD4MCuN Trim | CD4MCuN | Alloy 20 | Hastelloy B & C |
|---|---|---|---|---|---|
| 100 | Casing | Ductile Iron | CD4MCuN | Alloy 20 | Hastelloy |
| 101 | Impeller | CD4MCuN | CD4MCuN | Alloy 20 | Hastelloy |
| 105 | Lantern Ring (Not Illustrated) | Glass-Filled Teflon* | Glass-Filled Teflon* | Glass-Filled Teflon* | Glass-Filled Teflon* |
| 106 | Stuffing Box Packing (Not Illustrated) | Teflon* Impregnated Fibers | Teflon* Impregnated Fibers | Teflon* Impregnated Fibers | Teflon* Impregnated Fibers |
| 108 | Frame Adapter | Ductile Iron | Ductile Iron | Ductile Iron | Ductile Iron |
| 112 | Thrust Bearing | Double Row Angular Contact Conrad** | Double Row Angular Contact Conrad** | Double Row Angular Contact Conrad** | Double Row Angular Contact Conrad** |
| 122 | Shaft — Less Sleeve (Optional) | SAE4140 | 316SS | Alloy 20 | Hastelloy |
| 122 | Shaft — With Sleeve | SAE4140 | SAE4140 | 316SS | |
| 126 | Shaft Sleeve | 316SS | 316SS | Alloy 20 | Hastelloy |
| 136 | Bearing Locknut and Lockwasher | Steel | Steel | Steel | Steel |
| 168 | Radial Bearing | Single Row Deep Groove | Single Row Deep Groove | Single Row Deep Groove | Single Row Deep Groove |
| 184 | Stuffing Box Cover (Packed Box) | Ductile Iron | CD4MCuN | Alloy 20 | Hastelloy |
| 184M | Seal Chamber (Mechanical Seal) | Ductile Iron | CD4MCuN | Alloy 20 | Hastelloy |
| 228 | Bearing Frame | Cast Iron (Ductile Iron for STX Group) | Cast Iron (Ductile Iron for STX Group) | Cast Iron (Ductile Iron for STX Group) | Cast Iron (Ductile Iron for STX Group) |
| 250 | Gland | 316SS | CD4MCuN | Alloy 20 | Hastelloy |
| 262 | Repeller/Sleeve (Dynamic Seal Option) | — | CD4MCuN | Alloy 20 | Hastelloy |
| 264 | Gasket, Cover-to-Backplate (Dynamic Seal) | Teflon* | Teflon* | Teflon* | Teflon* |
| 265A | Stud/Nut, Cover-to-Adapter | 304SS | 304SS | 304SS | 304SS |
| 319 | Oil Sight Glass | Glass/Steel | Glass/Steel | Glass/Steel | Glass/Steel |
| 332A | INPRO Labyrinth Oil Seal (Outboard) | Stainless Steel / Bronze | Stainless Steel / Bronze | Stainless Steel / Bronze | Stainless Steel / Bronze |
| 333A | INPRO Labyrinth Oil Seal (Inboard) | Stainless Steel / Bronze | Stainless Steel / Bronze | Stainless Steel / Bronze | Stainless Steel / Bronze |
| 351 | Casing Gasket | Aramid Fiber with EPDM Rubber | Aramid Fiber with EPDM Rubber | Aramid Fiber with EPDM Rubber | Aramid Fiber with EPDM Rubber |
| 358A | Casing Drain Plug (Optional) | Steel | Alloy 20 | Alloy 20 | Hastelloy |
| 360 | Gasket, Frame-to-Adapter | Buna | Buna | Buna | Buna |
| 370 | Cap Screw, Adapter-to-Casing | Steel | 304SS | 304SS | 304SS |
| 412A | O-ring, Impeller | Glass-Filled Teflon* | Glass-Filled Teflon* | Glass-Filled Teflon* | Glass-Filled Teflon* |
| 418 | Jacking Bolt | 304SS | 304SS | 304SS | 304SS |
| 444 | Backplate (Dynamic Seal Option) | Ductile Iron | CD4MCuN | Alloy 20 | Hastelloy |
| 469B | Dowel Pin | Steel | Steel | Steel | Steel |
| 496 | O-ring, Bearing Housing | Buna Rubber | Buna Rubber | Buna Rubber | Buna Rubber |
| 761B | i-ALERT Condition Monitor | Stainless Steel / Epoxy | Stainless Steel / Epoxy | Stainless Steel / Epoxy | Stainless Steel / Epoxy |
* E.I. DuPont Reg. Trademark. ** LTX Power End features Duplex Angular Contact.
OEM reference: Goulds CV 3196 i-FRAME parts list and materials of construction. Item numbers are the OEM position references for identifying your installed pump's parts; the G196 CV power end uses the G196 general-purpose pump's position numbers where this page's fit section states so.
WCB carbon steel · CF8M / 316 stainless steel · CD4MCu · duplex stainless steel · CN7M / Alloy 20 · Monel · Nickel · Hastelloy B · Hastelloy C · Titanium · Zirconium alloy
Wider material requirements can be submitted with your enquiry. The material of each component — casing, impeller, cover and seal chamber — is confirmed for the selected pump size and fluid before quotation; a material in this list is a review route, not a blanket availability promise for every size.
For abrasive duty, consider wear resistance as well as corrosion resistance. Reduced contact between solids and the recessed impeller can limit impeller wear.
To meet ANSI B73.1M specifications, the OEM design offers a choice of stuffing box and seal chambers with a wide range of sealing arrangements. Identify the arrangement on your installed pump from the table — the supplied configuration is reviewed against it before quotation.
| Arrangement | OEM chamber | Notes |
|---|---|---|
| Packed box | Standard bore stuffing box | Teflon-impregnated fiber packing; throat bushing |
| Single inside seal | BigBore seal chamber | Flexibly mounted seal; TaperBore chamber used if a throat bushing is not required |
| Conventional single seal | BigBore seal chamber | — |
| Double seal | BigBore seal chamber | — |
| Cartridge seal | TaperBore PLUS seal chamber | — |
| Dynamic seal option | Repeller/sleeve (item 262) with backplate (item 444) | See items 262 / 444 in Appendix B |
| Item | STi | MTi | LTi | XLTi |
|---|---|---|---|---|
| Shaft — Diameter at Impeller | .75 (19) | 1 (25) | 1.25 (32) | 1.5 (38) |
| Shaft — Diameter in Stuffing Box/Seal Chamber (Less Sleeve) | 1.375 (35) | 1.75 (45) | 2.125 (54) | 2.5 (64) |
| Shaft — Diameter in Stuffing Box/Seal Chamber (With Sleeve) | 1.125 (29) | 1.5 (38) | 1.875 (48) | 2 (51) |
| Shaft — Diameter Between Bearings | 1.5 (38) | 2.125 (54) | 2.5 (64) | 3.125 (79) |
| Shaft — Diameter at Coupling | .875 (22) | 1.125 (29) | 1.875 (48) | 2.375 (60) |
| Shaft — Overhang | 6.125 (156) | 8.375 (213) | 8.375 (213) | 9.969 (253) |
| Shaft — Maximum Shaft Deflection | 0.002 (0.05) | 0.002 (0.05) | 0.002 (0.05) | 0.002 (0.05) |
| Sleeve O.D. thru Stuffing Box/Seal Chamber | 1.375 (35) | 1.75 (45) | 2.125 (54) | 2.5 (64) |
| Bearings — Radial | 6207 | 6309 | 6311 | 6313 |
| Bearings — Thrust | 5306 A/C3 | 5309 A/C3 | 7310 BECBM | 5313 A/C3 |
| Bearings — Bearing Span | 4.125 (105) | 6.75 (171) | 6.875 (164) | 9.25 (235) |
| BigBore Seal Chamber — Bore | 2.875 (73) | 3.5 (89) | 3.875 (98) | 4.75 (121) |
| Stuffing Box — Bore | 2 (51) | 2.5 (64) | 2.875 (73) | 3.375 (86) |
| Power Limits — HP (kW) per 100 RPM | 1.1 (.82) | 3.4 (2.6) | 6.6 (4.9) | 14.0 (10.5) |
| Maximum Liquid Temperature — Oil/Grease Lubrication without Cooling | 350°F (177°C) | 350°F (177°C) | 350°F (177°C) | 350°F (177°C) |
| Maximum Liquid Temperature — Oil Lubrication with Finned Cooler | 500°F (260°C) | 500°F (260°C) | 500°F (260°C) | 500°F (260°C) |
Dimensions: inches (mm).
OEM reference data from the Goulds CV 3196 i-FRAME brochure (sealing flexibility and construction details). These tables describe the OEM reference design so you can identify your installed pump's arrangement; the supplied G196 CV configuration is confirmed against your submitted seal and frame data before quotation.
Liquids with entrained air or gas are covered in the performance note above.
If the pump sits above the liquid source and needs to re-prime after shutdown, see the G3796 self-priming pump.
Crystal slurries in chemical and fertiliser production.
Stringy solids in pulp and paper, textile and food processing.
Wastewater and process streams containing large solids.
For the same pump size and frame, the G196 CV is dimensionally interchangeable with the installed CV3196: baseplate position, suction and discharge flange positions, coupling height and motor position are unchanged. Send the pump size, frame and a nameplate photo or GA drawing — final fit, duty, material and seal arrangement are confirmed before quotation.
The CV3196 family has seven hydraulic sizes: 2x2-8 (STi), 2x2-10, 3x3-10, 2x3-13 and 3x4-13 (MTi/LTi), 4x6-13 (LTi) and 6x8-15 (XLTi). Start from the size on your casing or nameplate and use the size table on this page to request a quote for that size; the installed frame is verified during the review.
In the OEM design, the CV3196 uses every Goulds 3196 part except the casing and impeller, and a retrofit kit of CV casing and recessed impeller converts an existing 3196 to the non-clog CV configuration. Send your 3196 size, frame and nameplate details and we will review the conversion scope for your installed pump before quotation.
Standalone supply covers the recessed impeller, the casing and cover (including the seal chamber), the shaft and shaft sleeve, and cartridge mechanical seals. Small parts such as seal rings, gaskets and bearings are not shipped on their own; they are supplied fitted to their assemblies. For any part, send the pump size, the OEM item or part number if known, the material and the quantity.
The OEM CV3196 constructions are ductile iron, CD4MCuN, Alloy 20 and Hastelloy B & C — the impeller is not offered in ductile iron. Wider material requirements, including 316SS/CF8M, Monel, nickel, titanium or zirconium, can be submitted with your enquiry; the exact material of each component is confirmed for the selected size before quotation.
The recessed impeller and concentric casing pass bulky and fibrous solids with minimum degradation — in the OEM wording, anything that can exit the discharge will pass through the pump. The OEM selection guide also rates the design for liquids containing 10–20% entrained air or gas. There is no single maximum solids size for the family: passage depends on the pump size and duty, so describe your solids, fibres and gas content with your enquiry.
Yes. A nameplate photo, the pump size or an OEM part number is enough to start; duty, material and seal details can be confirmed during the review. Lead time is confirmed with the quotation for the selected size and scope — our production lead times for comparable ANSI replacement pumps run 30–50% shorter than OEM lead times.
ENGINEERING SUPPORT
Send the pump size, frame or a nameplate photo — engineering reviews fit, duty, material and seal arrangement before quotation.