Skip to the engineering article

Engineering Insights

ISO Process Pump RFQ Checklist: The 6 Items That Get You a Quote, and the 12 That Get You the Right Pump

Prepare an ISO process pump RFQ with duty, liquid, materials, driver and installation data. Follow separate checklists for new pumps and replacement projects.

AC, DW and DN process pump family
Engineering source review Replacement-data workflow Updated Nov 25, 2026
RFQ essentials

Short answer

Six items get you a first quotation:

  1. Nameplate photo, or the model and size
  2. Flow, with units
  3. Total head, with units
  4. Liquid, concentration and temperature
  5. Material of construction
  6. Quantity

The 12 items in section 3 decide whether the pump that arrives is right — add them as soon as you have them.

Pump designation

1. Read the ISO 2858 size code

Read ISO 2858 as suction × discharge × nominal impeller diameter.

80-50-250 = DN80 suction, DN50 discharge, 250 mm nominal impeller.

Goulds 3196 size codes run the other way — discharge × suction. An 80-50 code on an ANSI pump and on an ISO pump are two different pumps.

Nominal impeller diameters in the size table include 125, 160, 200, 250, 315 and 400 mm.

Two pumps with the same ISO code share main dimensions and flange positions. Curves, impellers, seal chambers and spare parts are maker-specific.

Read the full ISO 2858 size table to check the nominal pump dimensions. For application selection, compare AC, DW and DN pump routes.

Specifications

2. Know which standard you are asking for

Standard Covers Use it for
ISO 2858 Designation, nominal duty points and principal dimensions. ISO 2858 pumps have a basic pressure rating of at least 16 bar at 20°C for cast iron, ductile iron, carbon steel and stainless steel. AC and DW series pressure executions: 16 / 25 bar. Interchangeable footprint
ISO 5199 (Class II) Technical requirements for centrifugal process pumps Chemical and process duty
ISO 9908 (Class III) Lighter technical requirements General industry and lower-risk duty
ISO 9905 (Class I) The most demanding ISO class Severe duty outside API specifications
ASME B73.1 ANSI process pumps ANSI RFQ checklist for US-standard plants
RFQ inputs

3. What each missing item costs you

Missing item What goes wrong
Specific gravity Motor undersized: 98% H₂SO₄ (SG 1.84) needs 1.84× the shaft power of water at the same duty and efficiency.
Viscosity at the coldest start Head and efficiency fall and power can rise. The pump misses its duty point.
Solids % by weight, max particle size, fibres Wrong route: general-purpose AC, wear-resistant DW or non-clogging DN.
Vapour pressure and lowest tank level The pump can cavitate when available NPSH is insufficient.
Minimum and maximum flow The pump runs far from BEP. Bearings and seals wear out early.
Frequency, 50 or 60 Hz If pump speed rises in the same ratio, the same impeller gives about 20% more flow and about 44% more head at 60 Hz.
Flange standard (EN 1092-1 PN16 vs ASME B16.5 Class 150) The pump arrives and does not bolt up.
Temperature range Wrong elastomer, impeller clearance or seal.
Seal type / API plan The seal chamber or gland clashes with the plant standard.
Motor: kW, voltage, enclosure, hazardous-area class The motor is rejected at site.
Retained interfaces (replacement RFQs) Piping, baseplate or coupling need modification on site.
Documents and tests Quotes are hard to compare. Missing items surface as extra cost after order.

Separate the first quotation from the technical inputs that settle the order. Specific gravity changes shaft demand and viscosity changes the operating curve, so send both at the temperatures the pump will actually see. Describe solids by concentration, size and shape. A wear problem, a blockage problem and clean transfer point towards different hydraulic routes. Attach the liquid data sheet and note the lowest tank level alongside the highest liquid temperature so the supplier can check the limiting suction case.

Send the minimum, normal and maximum flows together. The normal point drives the curve comparison while the extremes drive suction, power and minimum-flow checks. Record the actual supply frequency and any variable-speed range. A quote based on the wrong speed can move both head and absorbed power. The electrical package also needs voltage, enclosure and hazardous-area classification to identify the offered driver clearly.

For a replacement, cross-check the flange labels and drilling against the installed GA drawing. A nominal size tells the supplier which hydraulics to start from; the interface dimensions tell the shop whether the pump will fit the piping and base. Identify the seal arrangement and auxiliary connections on the same revision. Put inspection records and acceptance tests on the RFQ before requesting a price so every supplier includes the same evidence and the same test scope.

Replacement dimensions

4. Retained interfaces for a replacement

  • Flange sizes, positions and orientation
  • Flange standard, drilling, facing (RF/FF) and pressure class
  • Shaft centre height, foot bolt pattern and baseplate
  • Shaft extension diameter and length, coupling type and spacer length
  • Seal type and auxiliary piping connections

Send the GA drawing with its revision number, or measure these dimensions on the installed pump. Photos identify the pump; dimensions confirm the fit.

Mark each interface as retained or replaceable on the drawing. Use the pump centerline as the common reference for flange location, shaft extension and baseplate dimensions. Include the flange facing and drilling with each size. If the pipework will stay connected in its current location, record its orientation and the position of the mating faces. If the motor or coupling stays, identify the motor frame, shaft and coupling spacer so the offered assembly can be checked as a set.

Ask for the supplier’s GA drawing before approving dimensions. Put the offered dimensions next to the measured values and resolve any mismatch explicitly in the offer. Keep the approved revision with the purchase order and receiving inspection records.

Quotation scope

5. Supply scope and documents

Supply scope Items
Replacement parts Impeller, casing, cover, shaft, sleeve
Bare wet end Pump wet end
Complete pump Baseplate, coupling, guard, motor on request
  • GA and sectional drawing
  • Material certificates (MTR)
  • Casing hydrostatic test report
  • Impeller dynamic-balance record
  • Dimensional report
  • Performance test curve

List the documents you need in the RFQ — every supplier then quotes the same package.

Filled example

6. Example RFQ

Field Example entry
Request 65-50-200 replacement
Liquid 15% NaOH at 60 °C
Material CF8M
Seal Plan 11
Motor Reuse existing 22 kW motor
Retained interfaces EN 1092-1 PN16
Documents MTR 3.1, casing hydrostatic test report and impeller balance record
Quantity 1 pump and 1 spare impeller
Destination Rotterdam

Attach the installed nameplate and GA revision to this example, and mark which dimensions are retained. Show the retained motor separately from the new pump supply so its frame, speed and available shaft power can be checked against the proposed curve. Identify the spare impeller by the proposed size, material and finished trim. Include the actual flow and head from the plant record when submitting the request. Require the offer to identify the selected curve, supply boundary and document package.

Ask the supplier to confirm the hydraulic selection and the mechanical fit separately. The curve shows which trim reaches the duty. The drawing shows whether the pump flange faces, supports and shaft align with the retained installation. Request a part reference for the spare impeller so receiving can match it to the new assembly. Use the same tag or model reference on the offer, drawing, curve and parts list.

Bid review

7. How to compare quotations

Give each supplier the same duty cases, materials, supply scope, documents, tests and trade terms. Ask each supplier to list deviations and exclusions. Compare the quoted efficiency at duty, the NPSHR at maximum flow and the total price.

Total Dynamic Head Calculator · NPSH Calculator

Start with a common comparison sheet. Give each bidder the same liquid, operating cases, materials, document list, tests, delivery destination and trade terms. Put the requested scope and the offered scope in adjacent columns. Keep deviations and exclusions beside the item they change. A price for a bare wet end and a price that includes a baseplate, coupling, guard and test package describe different supply boundaries.

Compare the selected curve at the same operating point. Record efficiency at duty, NPSHR at maximum flow and the total price for the agreed supply scope. Review the returned GA drawing or retained interface dimensions alongside those hydraulic figures. Ask the supplier to identify the revision of every curve and drawing included in the offer. When a bidder changes a material, seal plan, test scope or driver, note that change in the comparison before choosing the offer.

Close the comparison with a record of the selected pump size, offered trim, retained interfaces and the documents due with the pump. Ask the supplier to list each test and the record it will deliver, including the measured configuration and the serial number that ties the result to the supplied equipment. Put drawing revisions and outstanding line items next to the responsible party. This gives procurement a way to compare the bids before award, and gives inspection a record to use when the pump arrives.

What to send with the RFQ

Pump identityNameplate photo or model and nominal size.
Duty and liquidFlow, total head, liquid, concentration and operating temperature.
Materials and quantityWetted material, required quantity and spare impeller scope.
Retained interfacesGA revision, dimensions, flange details and motor arrangement.
Supply and test scopeItems, documents, inspection and tests to include in the offer.

Send your RFQ

Send your RFQ: a nameplate photo plus the six items in the short answer starts the quotation. We confirm the size, the curve and the interface fit against your retained interfaces, and quote the pump, the scope and the document package as one offer.

miya_zhang@ansipumpspro.com

Send an ISO pump RFQ →

Common questions

Frequently asked questions

Can I send an RFQ with only a nameplate and photos?

Yes. The nameplate and photos identify the pump. Add flow, head, liquid, temperature, material and quantity, and the RFQ is quotable.

What does 65-50-160 mean on an ISO pump?

DN65 suction, DN50 discharge and a 160 mm nominal impeller diameter, in ISO 2858 designation order.

Are ISO 2858 pumps from different makers interchangeable?

The footprint and flange positions interchange. Impellers, curves, seal chambers and spare parts are maker-specific — order parts by the installed make and model, not by the ISO code alone.

What is the difference between ISO 5199 and ISO 9908?

ISO 5199 is Class II, the specification for chemical and process service. ISO 9908 is Class III, with lighter requirements for general industrial duty.

How do I make quotations comparable?

Send every supplier the same duty cases, scope, materials, documents and tests, and have each one list deviations and exclusions. Then compare price, efficiency at duty and NPSHR side by side.

Sources

References

References: ISO 2858; ISO 5199; ISO 9905; ISO 9908.

ANSI Pumps Pro engineering team, Zibo, China — manufacturing ANSI B73.1 pumps and parts since 2010

Engineering Review

Send the pump model, operating duty and available process data before selecting or replacing wetted components.

Request Engineering Review
Quick Quote